seizure detection algorithm
SzCORE as a benchmark: report from the seizure detection challenge at the 2025 AI in Epilepsy and Neurological Disorders Conference
Dan, Jonathan, Shahbazinia, Amirhossein, Kechris, Christodoulos, Atienza, David
Reliable automatic seizure detection from long-term EEG remains a challenge, as current machine learning models often fail to generalize across patients or clinical settings. Manual EEG review remains the clinical standard, underscoring the need for robust models and standardized evaluation. To rigorously assess algorithm performance, we organized a challenge using a private dataset of continuous EEG recordings from 65 subjects (4,360 hours). Expert neurophysiologists annotated the data, providing ground truth for seizure events. Participants were required to detect seizure onset and duration, with evaluation based on event-based metrics, including sensitivity, precision, F1-score, and false positives per day. The SzCORE framework ensured standardized evaluation. The primary ranking criterion was the event-based F1-score, reflecting clinical relevance by balancing sensitivity and false positives. The challenge received 30 submissions from 19 teams, with 28 algorithms evaluated. Results revealed wide variability in performance, with a top F1-score of 43% (sensitivity 37%, precision 45%), highlighting the ongoing difficulty of seizure detection. The challenge also revealed a gap between reported performance and real-world evaluation, emphasizing the importance of rigorous benchmarking. Compared to previous challenges and commercial systems, the best-performing algorithm in this contest showed improved performance. Importantly, the challenge platform now supports continuous benchmarking, enabling reproducible research, integration of new datasets, and clinical evaluation of seizure detection algorithms using a standardized framework.
Clinical translation of machine learning algorithms for seizure detection in scalp electroencephalography: a systematic review
Moutonnet, Nina, White, Steven, Campbell, Benjamin P, Mandic, Danilo, Scott, Gregory
Machine learning algorithms for seizure detection have shown great diagnostic potential, with recent reported accuracies reaching 100%. However, few published algorithms have fully addressed the requirements for successful clinical translation. For example, the properties of training data may critically limit the generalisability of algorithms, algorithms may be sensitive to variability across EEG acquisition hardware, and run-time processing costs may render them unfeasible for real-time clinical use cases. Here, we systematically review machine learning seizure detection algorithms with a focus on clinical translatability, assessed by criteria including generalisability, run-time costs, explainability, and clinically-relevant performance metrics. For non-specialists, we provide domain-specific knowledge necessary to contextualise model development and evaluation. Our critical evaluation of machine learning algorithms with respect to their potential real-world effectiveness can help accelerate clinical translation and identify gaps in the current seizure detection literature.
SzCORE: A Seizure Community Open-source Research Evaluation framework for the validation of EEG-based automated seizure detection algorithms
Dan, Jonathan, Pale, Una, Amirshahi, Alireza, Cappelletti, William, Ingolfsson, Thorir Mar, Wang, Xiaying, Cossettini, Andrea, Bernini, Adriano, Benini, Luca, Beniczky, Sándor, Atienza, David, Ryvlin, Philippe
The need for high-quality automated seizure detection algorithms based on electroencephalography (EEG) becomes ever more pressing with the increasing use of ambulatory and long-term EEG monitoring. Heterogeneity in validation methods of these algorithms influences the reported results and makes comprehensive evaluation and comparison challenging. This heterogeneity concerns in particular the choice of datasets, evaluation methodologies, and performance metrics. In this paper, we propose a unified framework designed to establish standardization in the validation of EEG-based seizure detection algorithms. Based on existing guidelines and recommendations, the framework introduces a set of recommendations and standards related to datasets, file formats, EEG data input content, seizure annotation input and output, cross-validation strategies, and performance metrics. We also propose the 10-20 seizure detection benchmark, a machine-learning benchmark based on public datasets converted to a standardized format. This benchmark defines the machine-learning task as well as reporting metrics. We illustrate the use of the benchmark by evaluating a set of existing seizure detection algorithms. The SzCORE (Seizure Community Open-source Research Evaluation) framework and benchmark are made publicly available along with an open-source software library to facilitate research use, while enabling rigorous evaluation of the clinical significance of the algorithms, fostering a collective effort to more optimally detect seizures to improve the lives of people with epilepsy.
Neonatal seizure detection from raw multi-channel EEG using a fully convolutional architecture
O'Shea, Alison, Lightbody, Gordon, Boylan, Geraldine, Temko, Andriy
A deep learning classifier for detecting seizures in neonates is proposed. This architecture is designed to detect seizure events from raw electroencephalogram (EEG) signals as opposed to the state-of-the-art hand engineered feature-based representation employed in traditional machine learning based solutions. The seizure detection system utilises only convolutional layers in order to process the multichannel time domain signal and is designed to exploit the large amount of weakly labelled data in the training stage. The system performance is assessed on a large database of continuous EEG recordings of 834h in duration; this is further validated on a held-out publicly available dataset and compared with two baseline SVM based systems. The developed system achieves a 56% relative improvement with respect to a feature-based state-of-the art baseline, reaching an AUC of 98.5%; this also compares favourably both in terms of performance and run-time. The effect of varying architectural parameters is thoroughly studied. The performance improvement is achieved through novel architecture design which allows more efficient usage of available training data and end-to-end optimisation from the front-end feature extraction to the back-end classification. The proposed architecture opens new avenues for the application of deep learning to neonatal EEG, where the performance becomes a function of the amount of training data with less dependency on the availability of precise clinical labels.